Corroision Inhibitor for Closed/Chilled Systems with Nitrite & Indicator
RXSOL-40-4020-025Advanced formulatory High performance Corrosion Inhibitor, nitrite borate based with antifungal Azole and alkalinity indicator for closed chilled system
Product Overview
Technical Specifications
Application & Dosage
Application Instructions
The system should be filled with good quality fresh or distilled water and where freeze protection is necessary, the proper amount of glycol-based antifreeze should be added. Begin circulating the system water, and add RXSOL-40-4020 cooling water treatment at an initial dosage of 8 liters per ton of system water capacity. Circulate for 30 minutes after addition to ensure good distribution and the establishment of a protective film. RXSOL-40-4020 cooling water treatment may be used with waters that have hardness contamination, provided the total hardness levels are less than 170 ppm or as otherwise recommended by the engine manufacturer, whichever is less. The chloride level in the cooling system should be limited to 100 ppm or as otherwise recommended by the engine manufacturer, whichever is less.
Recommended Dosage
|
Features |
Benefits |
|
Effective corrosion inhibitor |
Protects ferrous and non-ferrous metals Minimizes metal oxide deposits |
|
Contains a scale modifier |
Maintains heat transfer effectiveness Helps prevent overheating caused by sludge and mineral scale deposits Reduces cleaning and maintenance costs |
|
Liquid |
Easy to dose Cost effective |
|
Buffered |
Stabilizes cooling water pH |
Available Packaging & Quantities
RXSOL-40-4020 treatment is an effective corrosion inhibitor for ferrous metals in marine circulating cooling water systems. Because certain aluminum alloys are highly anodic, they may be difficult to completely protect. Therefore, the use of RXSOL LIQUID EWT treatment with systems containing aluminum alloys should be discussed with a local Rxmarine Marine representative prior to starting treatment. In order to ensure the maximum benefits from aRXSOL-40-4020 treatment program, the system should be inspected for deposits and corrosion. If the system is found to be contaminated, it must be chemically cleaned before the treatment program begins. Your Rx Marine representative can provide specific cleaning recommendations. Sacrificial anodes (magnesium or zinc) in the cooling system should be removed prior to adding RXSOL-40-4020 treatment.
Handling, Storage & Safety
|
Appearance |
Light yellow liquid |
|
Specific Gravity at 25° C (77° F) |
1.23 |
|
Flash Point (PMCC) |
None |
|
pH, Neat |
12.3 - 12.9 |
|
Freeze Point: |
-12.2° C (10° F) |
|
Freeze/Thaw Stability |
Complete |
#CorrosionInhibitorClosedChilledSystemsNitriteIndicator
#NitriteCorrosionInhibitor
#ChilledSystemCorrosionInhibitor
#NitriteBoraxCorrosionInhibitor