Hydrazine Hydrate 25 Kg
RXSOL-19-1541-025No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler )
Product Overview
Technical Specifications
Valuable Boiler Water Treatment Chemicals :
Hydrazine Hydrate (50 ~ 51% as N2H4) plays very important role for corrosion protection in boilers.
Activated Hydrazine (34 ~ 35% as N2H4) Catalyzed Hydrazine solution for corrosion Protection and related equipment.
Morpholine (C4H9NO). Technical Grade for Boiler Water Treatment. Purity Not less than 99%.
Acid Inhibitor : For the suppression of Hydrochloric Acid attack on Ferrous alloys, Cuprous alloys and Titanium alloys, effec up to 94°C with efficiency not less than 75% in 5% HCI solution and Acid Inhibitor concentration 2%.
Ammonia 25% (NH4OH).
25% as ammonium Hydroxide used high pressure Boiler water treatment.
It is a clear colorless liquid.
PH 11-12 @ 20 °C.
Density 0.9 g/cm3.
Chloride (CL) 0.002 mg/liter maximum.
Iron (Fe) 0.002 mg/liter maximum.
Hardness Stabilizer :
Polyacrylate material of low molecular weight.
Non-volatile used for scale inhibition in sea water treatment.
The product is miscible with water in all proportions. And is clear Liquid.
PH valve 5-7.
Density @ 20°C Approx. 40%.
Chemical Characterization Sodium Polyacrylate, Modified, Aqueous solution.
Solidification temperature -20°C.
Flash point >100°C.
Ignition temperature >200°C.
Application & Dosage
Application Instructions
Recommended Dosage
|
HYDRAZINE HYDRATE |
|
|
Test |
Results |
|
Appearance |
Colourless and clear |
|
Sulfate : as SO4 |
0.0001% max. |
|
Chloride : as Cl |
0.0001% max. |
|
Iron : as Fe |
0.00005% max. |
|
Heavy metals : as Pb |
0.0001% max. |
|
Non volatile matter |
0.005% max. |
|
Assay : N2H4H2O (as N2H4) |
80.19% (51.32%) |
Available Packaging & Quantities
The establishment of protective metal oxide lay-ers through the use of reducing agents (such as hydrazine, hydroquinone, and other oxygen scavengers) is known as metal passivation or metal conditioning. Although "metal passivation" refers to the direct reaction of the compound with the metal oxide and "metal conditioning" more broadly refers to the promotion of a protective surface, the two terms are frequently used interchangeably.
The reaction of hydrazine and hydroquinone, which leads to the passivation of iron-based metals, proceeds according to the following reactions:
| N2H4 | + | 6Fe2O3 | ® | 4Fe3O4 | + | 2H2O | + | N2 |
| hydrazine | hematite | magnetite | water | nitrogen |
| C6H4(OH)2 | + | 3Fe2O3 | ® | 2Fe3O4 | + | C6H4O2 | + | H2O |
| hydroquinone | hematite | magnetite | benzoquinone | water |
Similar reactions occur with copper-based metals:
| N2H4 | + | 4CuO | ® | 2Cu2O | + | 2H2O | + | N2 |
| hydrazine | cupric oxide | cuprous oxide | water | nitrogen |
| C6H6O2 | + | 2CuO | ® | Cu2O | + | C6H4O2 | + | H2O |
| hydroquinone | cupric oxide | cuprous oxide | benzoquinone | water |
Magnetite and cuprous oxide form protective films on the metal surface. Because these oxides are formed under reducing conditions, removal of the dissolved oxygen from boiler feedwater and condensate promotes their formation. The effective application of oxygen scavengers indirectly leads to passivated metal surfaces and less metal oxide transport to the boiler whether or not the scavenger reacts directly with the metal surface.
Handling, Storage & Safety
Hydrazine Hydrate supplier in Mumbai, Kolkata, Gandhidham, Chennai, Visakhapatnam, Fujairah, Dubai, Sharjah. Hydrazine Hydrate plays very important role for corrosion protection in boilers water treatment.
Target Industries & Supply Locations
Useful Applications
No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler )
The objective is to maintain a hydrazine residual between 0.05-0.2 ppm depending on operating pressure and boiler designe. Actual consumption is determined under operating conditions. A normal dosage is approximately 1 ltr. per day, depending of system layout.
Hydrazine is a convenient reductant because the by-products are typically nitrogen gas and water. Thus, it is used as an ANTIOXIDANT, an oxygen scavenger, and a corrosion inhibitor in water boilers and heating systems.
Hydrazine is mainly used as a foaming agent in preparing polymer foams.
No oxygen is entering the boiler with the feed water when hydrazine is present in the water.
Supply & Distribution Locations
Hydrazine is a convenient reductant because the by-products are typically nitrogen gas and water. Thus, it is used as an ANTIOXIDANT, an oxygen scavenger, and a corrosion inhibitor in water boilers and heating systems.
Hydrazine is mainly used as a foaming agent in preparing polymer foams.
No oxygen is entering the boiler with the feed water when hydrazine is present in the water.
Need pricing or a bulk quotation?
Tell us your required product and quantity — our technical sales team replies promptly with pricing and availability.